4 – Component Replacement

Replace the handle

Remove the handle

All replacement procedures for the Duramax Hyamp long handheld torches require the removal of the handle that
surrounds the trigger. To replace the handle, you need to remove the internal components from the handle.

1. Turn OFF (O) the power, disconnect the gas supply, and disconnect the torch.

2. Place the torch on a flat surface with the left handle facing up.

The left handle is the side with the screws.

3. Clamp the torch lead in place to keep it from moving.

4. Remove the screws from the left handle.

5. Insert a blade screwdriver between the handles, and gently twist the screwdriver to pry up the left handle. Being

careful to keep the trigger spring from launching out of the handle, lift the left side of the handle away from the torch.

Figure 2

Kit

Description

428277

Kit: Duramax Hyamp long handheld torch handle replacement

CAUTION!

Wear eye protection, as the trigger spring can launch out of the handle.