4 – Component Replacement

Replace the cap-sensor switch

Remove the cap-sensor switch

1. Turn OFF (O) the power, disconnect the gas supply, and disconnect the torch.

2. Remove all components from the upper and lower parts of the torch, including the consumables. See Remove the

handle on page 41 and Remove the front shell on page 47.

3. Remove the torch body from the rest of the torch. See Remove the torch body on page 58.

4. 0.6 m (2 foot) torches: Mark where the foam strip

is wrapped around the middle of the torch body’s gas tube so

that you can install a new strip in the same place.

1.2 m (4 foot) torches: Mark where the 2 foam strips

are wrapped around the middle of the torch body’s gas

tube so that you can install new strips in the same place.

Do not remove the foam strip at the top of the gas tube (near the torch head).

5. Peel the foam strip or strips off of the gas tube and discard. Also discard the cap-sensor switch

.

Figure 30

The 0.6 m (2 foot) torches contain only 1 foam strip around the middle of the torch body;
the 1.2 m (4 foot) torches (pictured above) contain 2 foam strips around the middle of the
torch body.

Kit

Description

428288

Kit: Duramax Hyamp long handheld torch cap-sensor switch replacement, 0.6 m (2 feet)

428289

Kit: Duramax Hyamp long handheld torch cap-sensor switch replacement, 1.2 m (4 feet)