Hypertherm Duramax Hyamp Long Handheld Torches User Manual
Page 63
Advertising
Duramax Hyamp Long Handheld Torches Service Manual 808290
63
4 – Component Replacement
10. Cover the pilot terminal screw and nut with the heatshrink included in the kit, as follows:
a. Leave 10 mm (3/8 inch) excess heatshrink above the screw.
b. Use a heat gun to warm the heatshrink until it adheres to the screw.
c. Close the end of the heatshrink by crimping it with a pair of pliers.
Figure 24
11. Connect the cap-sensor switch to the torch lead by pushing the mating plug on the torch lead wires into the socket
near the trigger end of the extension tube.
Figure 25
CAUTION!
Do not apply heat to the wires. Heating the wires can damage the connections in the torch lead.
Cap-sensor switch
Mating plug