Replace the torch lead, Remove the torch lead – Hypertherm Duramax Hyamp Long Handheld Torches User Manual
Page 73

Duramax Hyamp Long Handheld Torches Service Manual 808290
73
4 – Component Replacement
Replace the torch lead
Remove the torch lead
1. Turn OFF (O) the power, disconnect the gas supply, and disconnect the torch from the power supply.
2. Remove all components from the torch handle. See Remove the handle on page 41.
You do not need to disassemble the front shell or remove the extension tube to install a
new work lead.
3. Gently pull the cap-sensor switch connector and the pilot terminal screw (encased in heatshrink) out of the trigger
end of the extension tube.
4. Disconnect the cap-sensor switch at the trigger end of the extension tube by pressing the tab on the connector and
pulling the connector apart.
Figure 32
Kit
Description
Kit: Duramax and Duramax Hyamp hand torch lead replacement, 7.6 m (25 feet)
Kit: Duramax and Duramax Hyamp hand torch lead replacement, 15 m (50 feet)
Cap-sensor switch
Tab