Replace the torch lead, Remove the torch lead – Hypertherm Duramax Hyamp Long Handheld Torches User Manual

Page 73

Advertising
background image

Duramax Hyamp Long Handheld Torches Service Manual 808290

73

4 – Component Replacement

Replace the torch lead

Remove the torch lead

1. Turn OFF (O) the power, disconnect the gas supply, and disconnect the torch from the power supply.

2. Remove all components from the torch handle. See Remove the handle on page 41.

You do not need to disassemble the front shell or remove the extension tube to install a
new work lead.

3. Gently pull the cap-sensor switch connector and the pilot terminal screw (encased in heatshrink) out of the trigger

end of the extension tube.

4. Disconnect the cap-sensor switch at the trigger end of the extension tube by pressing the tab on the connector and

pulling the connector apart.

Figure 32

Kit

Description

428159

Kit: Duramax and Duramax Hyamp hand torch lead replacement, 7.6 m (25 feet)

428159

Kit: Duramax and Duramax Hyamp hand torch lead replacement, 15 m (50 feet)

Cap-sensor switch

Tab

Advertising