Installation and initial start-up – Ivoclar Vivadent P710 User Manual

Page 18

Advertising
background image

18

37

38

Step 5:
Hinging on the hood
Once all cables are properly connected to the furnace base, the hood
(36) can be hinged over the connections until it snaps into place.

Step 7:
Establishing additional connections
Power connection
Please make sure that the voltage indicated on the rating plate
complies with the local power supply. Subsequently, connect the
power cord (31) with the power socket of the furnace (30).

The furnace may only be used with the supplied power

cord!

Vacuum pump connection
Connect the vacuum pump plug (35) with the vacuum pump socket
(34).
We recommend using a vacuum pump from Ivoclar Vivadent, since
these pumps are especially coordinated with the furnace. If other
pumps are used, please observe and do not exceed the maximum
power consumption.

Do not shorten the vacuum hose! The minimum length of

the vacuum hose is 1.6 m.

Step 6:
Mounting the connection cover
Mount the connection cover (37) and secure it with the fastening
screw (38). When mounting the connection cover, make sure that
the catch springs on the sides snap into place.

The furnace may only be operated with the hood and the

connection cover mounted.

30

31

34

35

4. Installation and Initial Start-Up