5. Operation and Configuration

5.4.7 Maintenance programs
Scroll to page 3 in the home screen and press the
[Maintenance Programs] button.

The following programs are available in the Maintenance Programs
menu:
– Dehumidification program
– Cleaning program

2. Start the dehumidification program
Press START to start the dehumidification program.

5.4.7.1 Dehumidification
The condensation of water in the insulation of the firing chamber and the vacuum pump will result in a lower vacuum and
thus in impaired firing results. For that reason, the furnace head should be kept closed when the furnace is switched off or
the temperature is below 100°C, in order to prevent the absorption of humidity.

Conducting the dehumidification program:

1. Open the dehumidification program
Scroll to page 3 in the home screen and press the [Maintenance
Programs]
button. Press the [Dehumidification Program] button in
the Care Programs menu.