5. Operation and Configuration

Quick program selection
Pressing the P key switches to the program screen of the current program. When the program screen is shown, pressing
the P key again switches to the quick program selection by means of number entry.

Browsing the programs
If a program has been selected, the neighbouring programs can be
accessed by pressing the arrow buttons.

5.2.3 Program screen / Editing programs
If a program has been selected, the program screen is displayed. The firing programs can be changed or edited in this
screen.

For Ivoclar Vivadent programs, the write-protection must be deactivated first, before any parameters can be

changed.


The following information is displayed:
1. Information line
– Program designation
– Current furnace temperature

2. Firing curve
– Closing time, holding time
– Temperature increase, holding temperature, long-term

cooling

– Vacuum on, vacuum off

3. Program options
In addition to the parameters shown in the firing curve, several
other options are available that can be activated by pressing the
[Options]
button. The icons in the grid show the activated options.

4. IRT options
There are different operating modes available for the Program infrared technology, which can be selected using the [IRT]
button. The icon in the grid shows the activated IRT operating mode.

Editing parameters
Parameters are entered or edited in two steps.

Example: Setting the holding temperature

1. Press the [T] button.