Olson Technology MUSCLE-EM55X User Manual

Page 16

Advertising
background image

OTOT-EM55X/XL Optical Transmitter Rev. x1

www.olsontech.com

15

I/O ports of OTOT-EM55X (optional, XL-versions only)

The OTOT-EM55XL from hardware release 2.0 is optionally equipped with two (2) general purpose I/O and four (4)
input-only binary mode ports. The ports can be configured via the Webserver (HTTP) interface. The schematics of
these ports are given below.

Figure 6 — Schematic for I/O Ports

Figure 7 — Schematic for Input-only Ports

Notes:

• The maximum voltage applied to all ports should be not below GND level and should not exceed +5V

DC

.

• The input level for input high should be >3V; the input level for input low has to be < 1V for NEC hardware re-

lease 2.0.

• The input level for input high should be >1.6V; the input level for input low has to be < 0.8V NEC for hardware

release 2.1.

• The input-only port and the open drain output port have a pull-up resistor of about 100kOhms towards 3.3V.
• The active low output resistance to GND of the output port is < 210Ohms.

Advertising