OTOT-EM55X/XL Optical Transmitter Rev. x1

www.olsontech.com

42

Special Settings

CABLEwatch

®

NMS

Used Not

Used

SNMP Get/Set Community Names cannot be modified. (Web
and SNMP)

SNMP Get/Set Community Names can be modified. (Web
und SNMP)

Web Rackview and Rackview Configuration Pages Handling
are directly linked with CABLEwatch

®

NMS

Web Rackview and Rackview Configuration Pages are inde-
pendent from CABLEwatch

®

NMS

Rem.: A slot number must be assigned to all moduls without automatic slot detection (e.g. all 19 inch components. This has
to carried out by Rackview Configuration. The slot number acts as a reference number for all SNMP accesses.
Of all modules without slot assignment only one will be dis-
played in SNMP with slotnumber 50. All others are not
shown until they get a slotnumber assigned.

All modules without slot assignment are dispayed in SNMP
with the slot numbers 51, 52, ...

(**) available from NEC-E Software Release 1.11
Variables in the RFC1213 system group are write-protected.
it is possible to write sysLocation and sysContact indirectly
via the variables neLocationCity und NeLocationStreet of the
OLSON TECHNOLOGY-HFC862-HMSNE-MIB
(ahmsne.mib).

(**)Variables in the RFC1213 system group are writeable.
(however with restricted length, not 256 Byte !!)

HMS Traps Compliance

( see also SCTE-HMS-ALARMS-MIB und SCTE-HMS-COMMON-MIB )

Minor Compliant

(1)

Full Compliant

hmsAlarmEvent Trap is sent with ENTERPRISE OID alarm-
sIdent (1.3.6.1.4.1.5591.1.2), instead of OID scteHmsTree
(1.3.6.1.4.1.5591.1) as demanded by HMS MIB

As demanded by HMS MIB, hmsAlarmEvent Trap is sent
with ENTERPRISE OID scteHmsTree (1.3.6.1.4.1.5591.1).

hmsColdStart Trap is sent to RFC1215 with ENTERPRISE
OID commonIdent (1.3.6.1.4.1.5591.1.3), instead of OID
scteHmsTree (1.3.6.1.4.1.5591.1) as demanded by HMS MIB
and with Trap-Type COLD START.

As demanded by HMS MIB, the hmsColdStart Trap is sent
with the ENTERPRISE OID scteHmsTree
(1.3.6.1.4.1.5591.1) and with Trap-Type ENTERPRISE
SPECIFIC + Specific-Trap-Type 0.

HMS Notifications

Enabled

(1)

Disabled

All messages of type "Notification" are sent as Trap and are
inserted in the SNMP SCTE HMS tables. Since HMS does
not recognize Notifications, “HMS-Severity” minor is re-
ported

All messages of type "Notification" are not sent as Trap and
are not inserted in the SNMP SCTE HMS tables.
In the Webbrowser the Notifications are still shown

hfcInventory Format

T-Nova, E531i

(1)

DKS, T12-9

The SNMP variable "hfcInventoryFabricData" of the
T-NOVA-HFC-INVENTORY-MIB is provided in the format
defined by Biedenbach (T-Nova, E531i)

The SNMP variable "hfcInventoryFabricData" of the
T-NOVA-HFC-INVENTORY-MIB is provided in the format
defined by Herberg (DKS, T12-9)

(1) Default setting up to NECE Software Release 1.10

Trap Verify

If traps are to be transmitted via non permanent links like dial-up links (e.g. using ISDN or standard analog modem), it
is important to verify that the link to the trap receiver is working before any SNMP traps are sent. Otherwise, the traps
could get lost.

With NEC-E software 1.10.x and later, several settings have been introduced to obtain a verification of the link be-
tween the trap transmitter (=NEC) and trap receiver:

• Verify before trap. If enabled, via SNMP Get Request the “sysDescr” OID of the host having the “Trap Verify

Receiver” IP address (see below) is executed before the pending traps are sent. Only after successful reply all