OTOT-EM55X/XL Optical Transmitter Rev. x1

www.olsontech.com

53

Changing the OMI

totrms

(AGC on modes only)

The picture below shows, how to adjust the OMI total RMS, in order to optimize the transmission performance in
terms of CNR, CSO, CTB and BER.

Figure 42 — Setting the OMI Total RMS on the OTOT-EM55X

With software release 2.0, the OMI

totrms

(OMI

rms

in the figure beyond) is shown in %. In previous software releases,

OMI

totrms

was shown relative (in dB) to a nominal value. The display in % enables an easy comparison with the graphs

as shown in Figure 18. For that reason, OTOT-EM55X application software release 1.12 and later supports this fea-
ture.

Notes:

• OMI nominal refers to a factory setting and cannot be changed by the user.
• OMI

totrms

setting is only relevant in AGC-on mode.

• The setting range for OMI

totrms

might change slightly from device to device due to production tolerances.