Olson Technology MUSCLE-EM55X User Manual

Page 40

Advertising
background image

OTOT-EM55X/XL Optical Transmitter Rev. x1

www.olsontech.com

39

• Let´s guess, that I/O #0 is set to output on any warning (and alarm)
• Let´s guess, that I/O #1 is set to output on any alarm (no warnings)

Now let’s assume some alarm situations:

1. RF input of OTOT-EM55X is low (warning); Optical Amplifier has no warnings or alarms

The I /Os will be:

Output #0: active

Output #1: inactive

2. RF input level of OTOT-EM55XL is extremely low (alarm)

The I/Os will be:

Output #0: active

Output #1: active

3. Optical input power level of Optical Amplifier is low (warning); OTOT-EM55X has no warnings or alarms:

The I/Os will be:

Output #0: inactive

Output #1: inactive

4. Optical input power level of Optical Amplifier is low (warning); OTOT-EM55X has no warnings or alarms:

The I /Os will be:

Output #0: inactive

Output #1: inactive

5. Optical input power level of Optical Amplifier is low (warning); OTOT-EM55X has no warnings or alarms; I/O #2
is set to alarm on input;I/O #2 receives an alarm

The I /Os will be:

Output #0: inactive

Output #1: active

6. Optical input power level of Optical Amplifier is very low (alarm); OTOT-EM55X has no warnings or alarms:

The I /Os will be:

Output #0: inactive

Output #1: active