OTOT-EM55X/XL Optical Transmitter Rev. x1

www.olsontech.com

64

Index

Flag

Description

31

RESERVED

Reserved for the NMS Controller (Do not use these bits)

Flags in bold letters can be controlled via the limits menu.

Warning Flags

Index

Flag

Description

0

OUTPUT_PWR_LOW_WARNING

Optical output power is lower than the warning limit

1

LASER_HIGH_WARNING

The laser current of one laser is higher than the warning limit

2

TEC_HIGH_WARNING

The Peltier current of one laser is higher than the warning limit

3

RF_INPUT_LOW_WARNING

RF signal is lower than the warning limit

4

POWER_SUPPLY_WARNING

One of two power supplies fails (obsolete)

5

FAN_LEFT_WARNING

The left fan (looking from device's front side) fails

6

FAN_RIGHT_WARNING

The right fan (looking from device's front side) fails

7

OUTPUT_PWR_HIGH_WARNING

Optical output power is higher than the warning limit

8

RF_INPUT_HIGH_WARNING RF

signal

is higher than the warning limit

...

12

POWER_SUPPLY_LEFT_WARNING

The left power supplies (looking from device's front side) fails

13

POWER_SUPPLY_RIGHT_WARNING

The right power supplies (looking from device's front side) fails

14

OMI_OR_RFGAIN_LOW_WARNING

The calculated RF gain (if AGC on) or the calculated OMI (if AGC
off) is lower than the warning limit

15

OMI_OR_RFGAIN_HIGH_WARNING

The calculated RF gain (AGC on) or the calculated OMI (AGC off) is
higher than the warning limit

16

+3.3V_LOW_WARNING

Supply +3.3V is lower than the warning limit

17

+3.3V_HIGH_WARNING

Supply +3.3V is higher than the warning limit

18

+5V_LOW_WARNING

Supply +5V is lower than the warning limit

19

+5V_HIGH_WARNING Supply

+5V

is

higher than the warning limit

20

-5V_LOW_WARNING Supply

-5V

is

lower than the warning limit

21

-5V_HIGH_WARNING Supply

-5V

is

higher than the warning limit

22

+12V_LOW_WARNING

Supply +12V is lower than the warning limit

23

+12V_HIGH_WARNING

Supply +12V is higher than the warning limit

24

-12V_LOW_WARNING Supply

-12V

is lower than the warning limit

25

-12V_HIGH_WARNING Supply

-12V

is higher than the warning limit

26

N/A N/A

27

N/A N/A

28

LASER_TEMP_DIFF_LOW_WARNING

Laser temperature difference from nominal value is lower than the
warning limit

29

LASER_TEMP_DIFF_HIGH_WARNING Laser temperature difference from nominal value is higher than the

warning limit

30

MODULE_TEMP_LOW_WARNING Module

temperature is lower than the warning limit

31

MODULE_TEMP_HIGH_WARNING Module temperature is higher than the warning limit

Situations triggering a warning flag in the OTOT-EM55X; Flags in bold letters can be controlled via the limits menu.

Advertising
This manual is related to the following products: