Snmp trap configuration, 2 snmp trap configuration – QVidium QVSD User Manual

Page 31

Advertising
background image

User‟s Manual v.3

QVidium

®

QVSD H.264 SD Video

Codec™

Copyright 2011 QVidium

®

Technologies, Inc.Page 31 of 53

7.2 SNMP Trap Configuration

The H.264 SD Video Codec™ implements SNMP v1 and SNMP v2c traps to alert a
network management system (NMS) of certain problems that might arise. To enable
SNMP traps, you must enter the IP address of the NMS server where the SNMP trap
messages should be sent and check Yes under Send Traps. Below is the SNMP Trap
Configuration page that shows all the current trap configuration settings.

Figure 6: SNMP Trap Configuration.

For the encoder with traps enabled, an SNMP trap notification will be sent when the video input
loses or has no signal. It will also send a trap when the video input has been restored.

For the decoder with traps enabled, an SNMP trap notification will be send under any of the
following events:

The decoder detects that the incoming video packet stream has lost a packet

The network input has been disconnected or has no signal

The network input connection has been restored

A packet has not been recovered by the ARQ error correction (when ARQ is enabled)

For mode details, please see the MIB files.

Advertising
This manual is related to the following products: