Remko smart wp manager – REMKO WPM-Smart-Control-Manual for specialists-WKF-085 User Manual

Page 28

Advertising
background image

Circulation type

(dependent on which probes are used)

Impulse circulation:

If briefly dispensing water triggers an impulse on

the flow-operated safety device, this is registered

by the controller and the circulation pump is started

up. This means that the circulation is also active

when it is required.

Temperature-guided circulation:

Temperature-guided circulation keeps the hot

water temperature at the set temperature.

Select the circulation type with the rotary knob,

then confirm the entry with "OK".

Fig. 42: Selecting the circulation type

Menu item

Parameter

Factory setting

Circulation

type

Impulse

circulation

As required

Temperature-

guided circula-

tion

Press "Next".

Impulse-guided circulation -

Running time of the circulation

Switch-on time of the circulation pump after a dis-

pensing impulse.

If the circulation line is very short, a shorter running

time may suffice. If the time is not sufficient to

pump hot water to a remote dispensing point, the

running time must be extended.

To set the desired temperature, select it with the

rotary knob and confirm the entry with "OK".

Fig. 43: Impulse-guided circulation - Selecting the

running time of the circulation

Menu item

Parameter

Factory setting

Impulse-

guided circu-

lation - Run-

ning time of

the circula-

tion

1 min - 15 mins

5 mins

Press "Next".

REMKO Smart WP MANAGER

28

Advertising