Set temperature of the storage tank during

solar charging

Once the solar set temperature is reached, the

solar cycle pump is switched off. With the collector

cooling function activated, the temperature of the

storage tank can continue to rise as far as the set

maximum temperature.

The solar set temperature (select with the rotary

knob and confirm with "OK") should be reduced if

the hot water temperature is regularly too high or if

there is no thermostatic mixing valve installed. At

the same time, when the collector cooling function

is activated, the max. temperature of the storage

tank must be reduced.

Fig. 65: Set temperature of the storage tank

Menu item

Parameter

Factory setting

Solar set

temperature

5°C - 95°C

85°C

Press "Next".

Solar heating

If heating is to be provided from the available solar

yield (if required), this parameter must be acti-

vated.

If another heat generator is connected to the

system hydraulically, e.g. water-based chimney

heat exchanger, this parameter must be activated.

Fig. 66: Solar heating

Menu item

Parameter

Factory setting

Solar

heating

Deactivated

Deactivated

Activated

REMKO recommends installing a domestic hot

water mixer.

Once the last parameter has been entered into the

commissioning wizard, the screen switches to the

overview mode (3D house).