REMKO WPM-Smart-Control-Manual for specialists-WKF-085 User Manual

Page 35

Advertising
background image

Menu item

Parameter

Factory setting

Pump type

(solar cycle)

Asynchronous

pump

EC pump

Selection

according to

pump type

installed in the

solar cycle

Solar speed control system

Activate if you want the solar pump to modulate

according to solar capacity

Activation of the speed control system for the

pump in the solar cycle: the pump can be activated

according to demand, for efficiency reasons; as

solar radiation increases, the speed of the pump

increases.

When using a pump which is not suitable for the

speed control system, the system should be deac-

tivated.

(We recommend use of a speed-controlled pump).

Fig. 61: Activating the speed control system

Menu item

Parameter

Factory setting

Solar speed

control

system

Deactivated

Deactivated

Activated

Menu item

Parameter

Factory setting

Asynchro-

nous speed

control

system

On

On

Off

Medium flow rate probe

The amount of heat delivered from solar yields is

recorded continuously, and can be called up in the

form of a daily or cumulative value.

If no medium flow rate probe is installed, a manual

medium flow rate can be selected. The heat meter

can also be deactivated, if desired.

Fig. 62: Selecting the medium flow rate probe

Menu item

Parameter

Factory setting

Solar HM

Deactivated

Setting with

heat meter

installed

Manual medium

flow rate

Medium flow

rate probe

Press "Next".