7.3

Systems with a

photovoltaic plant

Systems

The smart heating function can be used with the

following variants:

n

Hybrid heat pump

n

Split air/water heat pump

either with or without solar heat, in each case.

Electrical connection of the heat pump

In order for the heat pump to be able to use the PV

power, the heat pump must be connected to the

same electrical connection as the PV plant. The

following connection variants are possible:

n

Connection of the heat pump to the household

electricity meter. The use heat pump power tar-

iffs is then not possible.

n

Connection of the heat pump to an electricity

meter with a heat pump power tariff. Feed-in of

the PV power via the household electricity con-

nection. The use of PV electricity by the heat

pump is then not possible, heat pump gradu-

ated tariffs can be used. However, it is possible

to switch over the heat pump at a later time.

Connection of the controller to the electricity

meters and inverter

In order to measure the output of the PV plant,

household electricity and heat pump, the controller

requires a connection to the electricity meters and

to the inverter of the PV plant. The controller uses

S0 interfaces for this purpose. Many electronic

power meters and many inverters already come

with such an interface integrated. In case no suit-

able units are installed or usable, reasonably-

priced meters can be purchased privately and

fitted.

WP

SN

PV

HH

Fig. 81: Connection diagram with separate power

meters

HH: Household

PV: Photovoltaics

SN: Mains

WP: Heat pump

WP

PV

HH

2

1

SN

Fig. 82: Connection diagram with power meters

from the energy supplier

HH: Household

PV: Photovoltaics

SN: Mains

WP: Heat pump

1:

Reference

2:

Feed-in

REMKO Smart WP MANAGER