"Settings" menu item (continued) - Expert

Authorisa-

tion level

Level 2 menu

item

Level 3 menu item

Level 4 menu item

Info

Heating /

cooling

Building adaptation

Building time constant

You can find

many of the indi-

vidual info texts

about the level

2-4 menu items

on your Smart-

Control

Standard heating load

Inertia of the heating curve

Mode

Room climate mode

Difference from cooling

limit

Difference from heating

limit

Floor screed drying func-

tion

After the floor screed

function we recommend

this function manually to

finish by deactivating!

Floor screed drying func-

tion status

Start / end temperature

Max.temperature

Heating phase increment

Drying time

Time at high temperatures

Incremental cooling phase

Time at low temperatures

Cooling

Cooling curve adjustment

Time programme

Setpoint increase

Room unit

Dewpoint monitoring

Cooling down (outside

temperature reference)

Floor screed function

Description

Value range

Factory setting

Customer

system

Floor screed function status

Activated / Deactivated

Deactivated

Start / end temperature

"10°C - 50°C"

20 °C

Max. temperature

"20°C - 50°C"

35°C

Incremental heating phase

0.0 K - 10.0 K

5.0 K

Drying time

0.0 h - 192 h

24 h

Time at high temperature

0.0 h - 192 h

96 h

Incremental cooling phase

0.0 K - 10.0 K

5.0 K

Time at low temperature

0.0 h - 192 h

24 h

REMKO Smart WP MANAGER

66