Activate/deactivate easy mode, Step procedure / description lcd indication – Remotec ZTS-110 V3.14 User Manual

Page 13

Advertising
background image

13

Activate/Deactivate Easy Mode 

The ZTS‐110 is default with Easy mode, below illustrates the functions of Easy mode: 
• Active functions:    Change Mode, change Fan mode and Temperature Scale selection 
• Inactive functions:  Scheduling, Program Mode, Clock Display, Setting Time, Setting Swing, Setting, 

Differential Set‐Point and Advanced Recovery Mode 

 
User can use Easy mode to disable Schedule function and the schedule will be controlled by Z‐Wave 
gateway. User can still change temperature and mode by pressing the local physical buttons. 

User can deactivate the Easy mode by local “Setting Mode” or Z‐Wave Configuration Parameter number 

8. (Please refer to Z‐Wave Configuration parameters table). 

 

Below is the example by local setting: 

Step  Procedure / Description 

LCD indication 

1

Press and hold  “Mode” key for 2 

seconds to entry the setting mode.

It will display “EASY YES” if it stays 

in Easy mode. Otherwise,   

it will display “EASY no” if Easy 

mode is deactivated. 

 

Press Up/Down key to toggle the 

selection. 

Press  “Prog"  key to confirm 

your settings. 

‐ It will go back to Home page if 

selected “YES”. 

‐ it will go to Day setting if selected 

“no". 

 

 
 
Temperature Scale selection in Easy Mode 
 

Step  Procedure / Description 

LCD indication 

Press and hold  “Prog"  keys for 

2 seconds to entry temperature F 

(Fahrenheit) ‐> C (Celsius) selection 

mode. 

 

Press Up/Down key to toggle the 

temperature F (Fahrenheit) ‐>     

C (Celsius) selection. 

Advertising