Wiring: 

z Be sure the operation mode is OFF and Fan selection is Fan Auto 
z Wire the proper cables at the terminal block according to the circuit diagram 
z Afterward, push all cables back into the wall 
z Do not use metal conduit or of cable provided with a metal sheath 
z Recommends adding fuse or protective device in the line circuit   
 

Terminals 

Symbol 

Cool changeover (heat pump) 

Heat changeover (heat pump) 

2nd Stage heater 

W2 

1st Stage heater 

W1 

Fan 

Compressor 

24Vac Power for Cooling   

RC 

24Vac Power for Heating   

RH 

24Vac Common 

 