40

Q  Can I use 2 or more ZTS‐110 in my house? What is the max. units if yes? 
A  Yes and it is very depends on the capability of gateway / controller. For example, gateway can 

supports up to 8, 16 or 32 ZTS‐110 in a network.   

 

Q   What is the recommended battery type for ZTS‐110 and what is estimated batteries service life? 
A  We recommend using alkaline batteries for ZTS‐110. 

Batteries service life is very depend on the number of usage per day. Normally, batteries service 
life is around 1 year while operated in FLiRS mode. 
If you are using battery and somehow it is in Z‐Wave Always Listening Mode, or if you are using 
battery as back up, and the AC power is down, the battery will drain very fast, battery will only 
survive 3‐5 days.   

 
 

Technical Specifications 

Model no. 

BW8031US (ZTS‐110US) 
BW8031AU (ZTS‐110AU) 
BW8031EU (ZTS‐110EU)   

RF frequency 

908.4MHz (US) (ZTS‐110US) 
921.4MHz (AU) (ZTS‐110AU) 
868.4MHz (EU) (ZTS‐110EU) 

RF operating distance 

up to 100ft outdoor line of sight, in unobstructed environment 

Z‐Wave association group 

Supports 3 association groups, max. 5 nodes ID can be assigned 
to these association groups. 

LCD 

TN type with white backlight 
VA=66.5mmx28.5mm 

Powered by 

Dry battery AA x 4pcs or 
24 VAC +/‐ 20% 50/60Hz 

Relay contact   

Voltage: 24 VAC 50/60 Hz 
Current: 1A Max. (inductive) 

Temperature measurable range 

32 – 99 °F / 0 – 40 °C 

Temperature display resolution 

0.5°F / 0.1 °C 

Temperature Setting range 

41‐99 °F / 5‐37 °C 

Temperature 

Operating: 32 – 122 °F / 0 – 50 °C 
Storage: 23 – 140 °F / ‐5 – 60 °C 

Dimension (L x H x T) 

145mm x 100mm x 25mm 

Weight   

170g (Batteries excluded) 

Z‐Wave device type   

Basic Device Class: Routing_Slave 

Generic Device Class: Thermostat 

Specific Device Class: Thermostat general v2 

Z‐Wave Command Class 

Controlled   Supported

COMMAND_CLASS_THERMOSTAT_FAN_MODE 

NO 

YES 

COMMAND_CLASS_THERMOSTAT_FAN_STATE 

NO 

YES 

COMMAND_CLASS_THERMOSTAT_MODE 

NO 

YES 

COMMAND_CLASS_THERMOSTAT_SETPOINT 

NO 

YES 

COMMAND_CLASS_THERMOSTAT_OPERATING_STATE 

NO 

YES 

COMMAND_CLASS_THERMOSTAT_SETBACK 

NO 

YES 

COMMAND_CLASS_SENSOR_MULTILEVEL 

NO 

YES 

COMMAND_CLASS_CLOCK 

NO 

YES 