Physical Installation and Wiring 

L CAUTION 

− We  highly  recommend  that  this  installation  procedure  is  performed  by  a  trained  HVAC 

technician. 

− Read the enclosed instructions carefully before installing your new Z‐Thermostat. Pay close 

attention  to  all  warnings  and  notes  and  carefully  follow  the  installation  steps  in  the  order 
they  are  presented  to  save  time  and  minimize  the  risk  of  damaging  the  thermostat  or  the 
system it controls. 

− Turn off ZTS‐110 and the electronic devices (e.g. heater, cooler) which will be connected and 

the electric source before installation and maintenance. 

 

Battery safety! 

− Use new batteries of the recommended type and size only. 
− Never mix used and new batteries together. 
− To avoid chemical leaks, remove batteries from the ZTS‐110 if you do not intend to use the 

unit for an extended period of time. 

Dispose of used batteries properly; do not burn or bury them.

 

Read following scenarios carefully before you start as it matters to the battery life under Z‐Wave 
operation:   
ZTS‐110 can be powered by 4 x AA batteries, and/or 24Vac C wire.   
a) If  it  is  powered  by  batteries  or  powered  by  batteries  first  then  applied  with  24Vac  before 

Z‐Wave  inclusion,  ZTS‐110  will  self‐configure  to  FLiRS  mode  which  will  save  battery  life  by 
sleeping.   

b) If it is powered by 24Vac or powered by 24Vac first then applied with batteries before Z‐Wave 

inclusion, ZTS‐110 will self‐configure to Always Listening Mode which will not sleep.   

c) After  inclusion  process,  ZTS‐110  will  not  detect  power  source  and  not  allow  changing 

operation mode. You must perform exclusion process first if need to change Z‐Wave operation 
mode. 

d) After Z‐Wave inclusion process, if you reset ZTS‐110 to default while both 24Vac and batteries 

are  applied,  ZTS‐110  will  take  24Vac  as  primary  power  source  and  self‐configure  to  Always 
Listening Mode, because reset to default process will automatically exclude ZTS‐110 from the 
Z‐Wave network. You should disconnect the power source and re‐apply the power so ZTS‐110 
can detect the power source type and self‐configure to corresponding mode. 

You may check Glossary for the definition of FLiRS mode and Always Listening Mode.   