TE Technology TC-36-25-RS485 User Manual

Page 10

Advertising
background image

 

10

Main Features 

 RoHS compliant 
 Operates as a stand‐alone controller or with a computer monitor 
 Bi‐directional, solid‐state H‐bridge operation for both heating and cooling 
 Can be configured to control both high and low voltage thermoelectric (TE) devices: 

 Single power supply configuration for TE devices with an input voltage range from (12 to 36) VDC 

 Dual power supply configuration for TE devices with an input voltage range is less than 12 VDC: 

o

Controller‐circuitry input voltage range from (12 to 36) VDC 

o

TE device (H‐Bridge) input voltage range from (0 to 36) VDC 

 Maximum 25 A current rating, controls up to 900 W 
 Soft‐start features turns the output on slowly, over a one second period 
 Over current shutdown that can be set in 2.5 A increments 
 Open sensor and shorted sensor output shutdown with automatic restart 
 Low Voltage shutdown protects the H‐bridge when the control circuitry voltage is less than 12 VDC 
 Pulse width modulation of output at 2700 Hz 
 RS‐485 communication protocol 
 Computer programmable settings and monitoring 
 Control temperature of –20 °C to +100 °C using thermistor supplied with controller 
 Control temperature of –40 °C to +250 °C using optional thermistors 
 Proportional (P), Integral (I) and Derivative (D) control that can be selected as P, PI, PD or PID; or Deadband 

(on/off) with an adjustable hysteresis 

 Temperature resolution of 0.01 °C or 0.01 °F 
 Control stability of ±0.01 °C or ±0.01 °F (best case, when controlling a cold plate) 
 Set temperature adjustable by several options: 

o

Computer set via software 

o

Remote potentiometer (customer supplied) 

o

0 mA to 20 mA current loop 

o

0 VDC to 5 VDC adjustable range 

o

Differential temperature control (allows control to a programmable temperature difference above or below 
the temperature of the second thermistor, if used) 

o

MP‐2986 Display and Keypad (optional accessory) 

 No computer programming experience required to use the communications software program (Supplied 

software is compatible with Windows 95/98/XP/NT) 

 Command set is provided so programmers can create their own software interface or embedded controller 

applications 

 Versatile alarm system: 

o

Computer configurable alarms for 25 mA, with a compliance voltage up to 11 VDC 

o

Alarm cancel:   selectable via computer‐software communication or remote contact closure 