When this is turned on, any changes to software settings at run time are stored in EEPROM as well as RAM. The 
values can then be recalled upon a power‐up or reset condition. The maximum number of writes to an EEPROM 
location is 1,000,000. So, you may want to keep this setting off most of the time in order to avoid this limit. 
 
When this is turned off, any changes to software settings are only stored in RAM. No settings are saved to 
EEPROM. This setting gives you the ability to change run‐time settings without changing desired power‐up settings. 
This allows you to make unlimited changes to run‐time settings without having to write to EEPROM. 

 
2.4.2 EXTERNAL DISPLAY ENABLE 

The optional MP‐2986 display will display the set temperature and input 1 (primary thermistor) reading if this is 
enabled.   

 
2.4.3 SAMPLE DELAY and SAMPLE INTERVAL 

Enter a SAMPLE DELAY to set an estimated time interval between when data samples are taken. Because there can 
be up to 255 controllers communicating on the same network, the sample time interval set in SAMPLE DELAY can 
be different than the actual sample interval.  This varies with the number of controllers in the network, alarm 
conditions, number of controllers being scanned and if data is being saved. The SAMPLE INTERVAL displays the 
actual sample period. 

 
2.4.4 SAVE DATA TO FILE 

Each sample can be saved to a file in the SAVE FILE box.  The data saved is the controller address, sample time, and 
the temperature sensed on input 1 (primary thermistor) for each controller being scanned. 

 
2.4.5 DOWNLOAD DEFAULTS 

The DOWNLOAD DEFAULTS section is used to reprogram all settings in the controller with the factory defaults. The 
index control can be used to view the default settings. Clicking the GO button will program the controller in the 
ADDRESS box with these settings. 

 
2.4.6 CHANGE CONTROLLER ADDRESS 

The allowable address range is from 1 to 255, but not 99. Addresses 0 and 99 are reserved. Do not program a 
controller with a reserved address. A unique address number needs to be assigned to each controller on a multi‐
controller network to prevent communication errors.  

 

NOTE:  Programming two or more controllers with the same address will cause communication errors.  If this 
occurs, place a jumper between JP2‐1 and JP2‐4 in one of the controllers to set the address to 99 (as described 
previously in Section 2.0). Alternatively, remove one of the controllers from the network, and reprogram it 
separately with a unique address before returning it to the network.   

 

 