Operation

3 -11

PRISM 3000

User Info/Unit ID: The idle screen top line may be
changed in this field. Text is entered using the up and down
arrow keys to scroll through each character and the right
arrow key to change cursor position. The original text can be
restored by pressing <Exit> at any time during the editing
process. The screen is shown below.

User Info / Unit ID Display Screen

NMS Address: When used with the EM8000 element man-
ager, each PRISM unit connected to the local daisy chain
must be programmed with a unique address in the range of

1

’ through ‘

250

’. To program a number, scroll through the

digits with the up and down arrow key. Press the right arrow
key to select a digit. A valid NMS address must be selected
before the configuration can be recalled upon start up.

After software has been downloaded into the flash memory,
the RAM must be cleared. This process sets the NMS
address to ‘

000

’. If the unit is then powered down with this

address, it will reboot with the NMS address of ‘

251

’.

NMS Bit Rate: This field sets the interface speed for the

NMS

IN

’ and ‘

NMS

OUT

’ ports. The selections are ‘

1200

’,

2400

’, ‘

4800

’, ‘

9600

’, and ‘

19200

’ bps.

Supv Bit Rate: This field sets the interface speed for the
supervisory port (

SUPV

). The selections are ‘

1200

’,

2400

’, ‘

4800

’, ‘

9600

’, and ‘

19200

’ bps.

Boot Mode: When the PRISM unit is powered, its config-
ured is based on this selection. If set to ‘

LOCAL

’, the unit

restores the configuration parameters in effect when power
was lost. If set to ‘

NMS

’, the unit will use the configuration

parameters supplied from the EM8000 element manager
database (the unit must have a valid NMS address - from 1
to 250). As shipped from the factory, the unit uses the fac-
tory default configurations stored in the ‘

LOCAL

’ memory.

Alarm Cutoff: When this menu item is set to ‘

DISABLE

’,

the PRISM reports a network interface alarm condition by
lighting the front panel indicator and activating the alarm
relay contacts on the rear panel. When set to ‘

ENABLE

’, the

front panel ‘

ALARM

’ indicator still lights during an alarm

condition, but the alarm contacts are forced to an inactive
state regardless of the alarm status.

Call on Alarm: This field controls remote alarm reporting.
Three submenus are available as follows:

Alarm Notification:

[

OFF

] - Disables alarm reporting.

[

DIRECT

] - Sends reports to a printer or terminal con-

nected directly to the supervisory port.

[

DIAL

] - Sends reports through an attached ‘AT’ com-

mand set compatible modem connected to the ‘SUPV’
serial port, which must dial out to a remote modem.

[

DIAL

NMS

] - Calls the EM8000 to dump alarms directly.

Edit Primary and Secondary Dial String:

These fields are 18-character ASCII strings for the call on
alarm phone numbers used in the [

DIAL

] and [

DIAL

NMS

] modes. The unit attempts 3 times to connect using

the primary number. If all 3 attempts fail, it will attempt 3
times to connect using the secondary number (if it is not

TxPORT PRISM 3000

/ =Letter

Select=Done

= move

Display

View Angle

Date

Time

Edit

Password

User Info

Unit ID

Call On

Alarm

Adjusts front panel

screen contrast.

The default value

is 8.

Enter current

date in

MM:DD:YY

format.

Enter current

time in

24- hour

HH:MM:SS

format.

Enter line of

text, such as

site location,

circuit ID for

idle top line

Off

Direct

Dial

Dial NMS

Remote

Link

FDL

Ch. 1 - 24

None

NMS

Address

Enter 3 digits

in range of

1 - 250.

The default
value is 251

NMS

Bit Rate

1200
2400
4800
9600

19200

SUPV

Bit Rate

1200
2400
4800
9600

19200

Boot

Mode

Local

NMS

Alarms

Cut Off

Disable

Enable

Alarm

Notifi-

Edit

Primary

Edit

Second.

Edit

Element

Enter up to 10

characters using

and keys.

Accept and move

with right arrow.

System Utilities Menu Diagram

cation

String

String

ID