Configuration 3-3

PRISM 3101/3102

Switch S4

Switch S4 (Figure 3 -5) configures the T1 DTE port. Any
channel not mapped to a data port is mapped to the T1 DTE
port. Linecoding on the T1 DTE is independent of T1
linecoding.

DTE Framing: Switch S4-1 selects the framing type for the
DTE side of the element as either ESF (Dn) or D4 (Up).

DTE Coding: Switch S4-2 sets the DTE side line coding as
either B8ZS (Dn) or AMI (Up).

DTE DSX Level: Switch S4-3, S4-4, and S4-5 set the DTE
line build-out signal level as identified in Table 3-F.

Software Configuration

The terminal interface is a firmware application program
embedded inside the PRISM 3101/3102. You can access
this information through the LAN port (page 2-2), SUPV
port (page 2-3), or SLIP port (page 2-3) using a TELNET
session.

Interface Start-up

Once a compatible terminal is properly connected to the
unit, you can start a terminal interface session by sending a
BREAK command to the unit (or by pressing <return> four
times). The Main Menu screen is displayed if a password
has not been specified.

If a password has been previously establish, you must enter
the correct password to continue the session. The password
is case-sensitive.
If you have forgotten your password, note
the date and time shown on your screen and contact
TxPORT Technical Support. You can establish a password
through the Utilities screen on page 3-17.

Menu Structure

The terminal interface opens with a main menu allowing
five options: Alarms, Performance, Maintenance, Configu-
ration, and Utilities (Figure 3-6). Each menu screen allows
you to access the local or far end menu screen.

For more information on terminal interface conventions,
refer to Appendix A, Terminal Interface.

If you do not enter a keystroke for
10 minutes, the terminal interface

automatically logs off.

Table 3-F DTE DSX

S4-3

S4-4

S4-5

0-110 ft

Dn

Dn

Dn

111-220 ft

Up

Dn

Dn

221-330 ft

Dn

Up

Dn

331-440 ft

Up

Up

Dn

441-550 ft

Dn

Dn

Up

551-660 ft

Up

Dn

Up

661 ft >

Dn

Up

Up

7

6

5

4

3

2

1

Dn

Up

8

DTE

DTE

DTE

LBO

Not Used

Fra

m

ing

C

o

di

ng

No

t Us

ed

Not Used

DTE

LBO

Switch

S4

DTE L

B

O

Figure 3-5 Switch S4

Alarms

MAIN

MENU

Log

Off

Log

On

Performance

Maintenance

Configuration

Utilities

Standard 24 - Hour

Enhanced 24 - Hour

Standard 30 - Day

Enhanced 30 - Day

Line Parameters

Alarm Parameters

Port Parameters

TCP/IP Parameters

SNMP Parameters

Management Ports

Summary

DBU Parameters

Figure 3 -6 Menu Structure

Advertising
This manual is related to the following products: