Monitoring pfc500/e status – Grass Valley PFR 500/E Dec 10 2001 User Manual

Page 43

Advertising
background image

Monitoring PFC500/E status

November 17, 2000

PFC 500/E Instruction Manual

43

Status lights visible at the back of the PFC500/E

If the RC Check light is on, you should look at the other Check lights to determine
which CRU is faulty. If a check light on a CRU remains on, you should replace that
CRU as soon as possible.

If a non-redundant CRU fails in a PFC 500, the system may be inoperable while you
replace the CRU. If a redundant CRU fails, high availability will be compromised
until you replace the faulty CRU.

Light

Quantity

Color

Meaning

Active

1 per RC

Green

On when the RC is powered up.

RC Check

1 per RC

Amber

On when either the RC or a Fibre Channel
connection is faulty.

Power Supply Active

1 per supply

Green

On when the power supply is operating.

Power Supply Check

1 per supply

Amber

On when the power supply is faulty or is
not receiving ac line voltage.

Cooling Check

1 per supply

Amber

Flashing when either multiple fans in the
drive fan pack are faulty or the drive fan
pack is removed. The RC powers down
the disk drives and goes into standby
mode when the fault persists for more
than about two minutes.

Drive Fan Pack Check

1 on drive
fan pack

Yellow

On when a fan in the drive fan pack is
faulty.

Advertising