Tnc error messages with digitizing -25 – HEIDENHAIN TNC 360 User Manual User Manual
Page 235

12-25
TNC 360
12
Tables, Overviews, Diagrams
12.6 TNC Error Messages
TNC error messages with digitizing
AXIS DOUBLE PROGRAMMED
Program two different axes for the coordinates of the starting point
(CONTOUR LINES cycle).
EXCHANGE TOUCH PROBE BATTERY
Exchange the battery in the touch probe head (TS 511). This message is
displayed when the probe reaches the end of a line.
FAULTY RANGE DATA
• Enter MIN coordinates that are smaller than their MAX coordinates.
• Define the RANGE within the limits set by software limit switches.
• Define the RANGE for the MEANDER and CONTOUR LINES cycles.
MIRRORING NOT PERMITTED
Reset all coordinate transformations before digitizing.
PLANE WRONGLY DEFINED
Define the starting position coordinates (CONTOUR LINES cycle) in axes
different from the stylus axis.
PROBE SYSTEM NOT READY
• Orient transmitting/receiving window of TS 511 to face receiving unit.
• Check that the touch probe is ready for operation.
• The touch probe cannot be retracted (collision with workpiece).
RANGE EXCEEDED
Enter a RANGE that includes the entire 3D surface to be scanned.
ROTATION NOT PERMITTED
Reset all coordinate transformations before digitizing.
SCALING FACTOR NOT ALLOWED
Reset all coordinate transformations before digitizing.
START POSITION INCORRECT
Program the starting point coordinates for the CONTOUR LINES cycle so
that they lie within the RANGE.