TNC 360
2-20
2
Manual Operation and Setup
Fig. 2.17:
Measuring lengths with the 3D
touch probe
or
2.6
Measuring with the 3D Touch Probe System
1
Y
X
Z
l
2
END
.
.
.
0
ENT
I
Measuring workpiece dimensions
Select the SURFACE = DATUM probe function.
Move the probe to a starting position
1
near the first touch point.
SURFACE = DATUM
X + X – Y + Y – Z + Z –
Select the probing axis and direction.
Probe the workpiece.
If you will need the current datum later, write down the value that appears in the DATUM display.
DATUM X =
Set the DATUM to 0.
Terminate the dialog.
Re-select the SURFACE = DATUM probe function.
Move the touch probe to a starting position
2
near the second touch point.