Cc-link option led display, Setting station address, 4 cc-link option components – Yaskawa 1000 Series Drive Option - CC-Link Installation User Manual

Page 12

Advertising
background image

4 CC-Link Option Components

12

YASKAWA ELECTRIC TOBP C730600 44A YASKAWA AC Drive-Option Card CC-Link Installation Manual

Figure 3

Figure 3 CC-Link Option Terminal Block

CC-Link Option LED Display

Table 3 CC-Link Operation LED Status

Setting Station Address

Set drive parameter F6-10 to a station address (Range 1 to 64) unique to the network. If set

to 0, the L.ERR light will turn on and a Station Address Error (AEr) will occur.

Name

Indication

Operating

Status

Remarks

Color Status

L.RUN Green

ON

Normal
operation

• Receiving data normally

OFF

Timed out

• Timed out waiting to receive
• Logging onto the network
• During reset

L.ERR

Red

ON

CRC error

• CRC error
• Station address setting error (F6-10 = 0)

OFF

During
communications

• Normal communications
• During reset

SD

Red

ON

Sending data

• Sending data

Note: LED may appear to flash with slower baud rates.

OFF

No data transfer

• No data being sent
• During reset

RD

Red

ON

Detecting data
received

• Detecting data that was received

Note: LED may appear to flash with slower baud rates.

OFF

Waiting for data

• Data not yet received
• During reset

Top View

DA DB DG SLD SLD

Side View

Advertising
This manual is related to the following products: