5 Installation Procedure

YASKAWA ELECTRIC TOBP C730600 44A YASKAWA AC Drive-Option Card CC-Link Installation Manual

15

Connection Diagram

Table 4 Connection Diagram

Using a single drive

<1> The user must set up the drive for terminal resistor. For instructions, see

Terminal Resistor Connection on

page 19

.

<2> Make sure that the FG terminal on the master drive is grounded properly.

<3> The FE terminal on the CC-Link Option is supplied with a ground cable that should be connected to the ground terminal

on the drive.

Using multiple drives

CC-Link

Option

DA

DB

DG

SLD

SLD

DA

DB

DG

SLD

FG

Master
device

CC-Link cable

DRIVE

Terminal resistor

<1>

FE

<2>

<3>

CC-Link

Option

DA

DB

DG

SLD

SLD

CC-Link

Option

DA

DB

DG

SLD

SLD

DA

DB

DG

SLD

FG

CC-Link

Option

DA

DB

DG

SLD

SLD

Master
device

DRIVE

DRIVE

DRIVE

CC-Link cable

Terminal resistor

<1>

FE

FE

FE

<2>

<3>

<3>

<3>