5 installation procedure – Yaskawa SI-EP3 PROFINET Installation User Manual
Page 19
Advertising

5 Installation Procedure
YASKAWA TOEP YEACOM 07A 1000-Series Option PROFINET SI-EP3 Installation Manual
19
4.
Connect the ground wire (L) to the ground terminal (N) using one of the remaining
provided screws (K). Connect the other end of the ground wire (L) to the remaining
ground terminal and installation hole on the option (E) using the last remaining
provided screw (K) and tighten both screws to 0.5 ~ 0.6 nm or (4.4 ~ 5.3 in lbs).
Figure 6
Figure 6 Connect the Ground Wire
Note: There are two screw holes on the drive for use as ground terminals. When connecting three
options, two ground wires will need to share the same drive ground terminal.
NS
MS
K
L
E
N