6 Option Related Drive Parameters

26

YASKAWA TOEP YEACOM 07A 1000-Series Option PROFINET SI-EP3 Installation Manual

F7-33

to

F7-37

Dynamic Input
Assembly
Parameters
(SI-EP3 Firmware
Version VST800250)

Configurable inputs 1 to 5.
If a value other than 0 is assigned to parameters F7-23 to
F7-27 and F7-33 to F7-37 by the drive, that value will take
precedent over a value set by the configuration software.
If the value in the drive is 0 (default), the value from the
configuration software will be used.

0

Dynamic Input
Assembly
Parameters
(SI-EP3 Firmware
Version VST800251)

Configurable outputs 1 to 5.
If a value other than 0 is assigned in the configuration
software, those values will be used, otherwise, the values of
the drive parameters set in parameters F7-23 to F7-27 and
F7-33 to F7-37 will be used.

H5-11

Communications
ENTER Function
Selection

Select the function for the ENTER command that saves
parameter data to the drive.
0: Parameter changes are activated when ENTER command
is written
1: Parameter changes are activated immediately without use
of ENTER command

1

<1> To start and stop the drive with the option master device using serial communications, set b1-02 to 3. To control

the drive frequency reference via the master device, set b1-01 to 3.

<2> If F6-01 is set to 3, 4, or 5, then the drive will continue to operate when a bUS fault is detected. Take proper safety

measures, such as installing an emergency stop switch.

<3> The availability of this feature/function is depends on drive model, software version and Profinet firmware

version. Refer to

Table 15

for specifics relating to your drive.

No.

Name

Description

Default