7 Web Interface

YASKAWA TOEP YEACOM 07A 1000-Series Option PROFINET SI-EP3 Installation Manual

37

Parameter Access Tab

The Parameter Access tab allows the user to read and write parameters from the drive. Write

access is restricted until a valid password is entered.

Figure 17

Figure 18 Parameter Access Tab View

The MEMOBUS/Modbus address for the drive parameter being accessed must be entered in

hexadecimal. The number must begin with “0x” to signify hexadecimal.
Clicking “Read” will load and display the current value of the given MEMOBUS/Modbus

Address. Clicking “Set” will save the given value to the given MEMOBUS/Modbus address.
After a “Read” or “Set” command is given, Status will display “Waiting” while the action is

being carried out, then “Complete” is displayed when finished.