2 Spindle Orientation

12

YASKAWA TM.A1000SW.063 Spindle Orientation A1000 Custom Software Supplement

P1-10

0609h

Orientation Encoder Card Selection
ORT Enc Select

This parameter selects which PG option card is used
for orientation.

0: CN5-C
1: CN5-B

Note: When using only one PG option card, P1-10
must be set to 0.

0 to 1

0

No

– – – Y– – N

P1-11

061Eh

Orientation Deceleration Selection
ORT Dec Sel

This parameter selects whether the drive’s C1-0…
Deceleration Time is overridden by the P1-12
Orientation Deceleration Time once the drive
reaches the P1-01 Orient Speed.

0: Disabled
1: Enabled

0 to 1

0

No

– – – Y– – N

P1-12

061Fh

Orientation Deceleration Time
ORT Dec Time

The Orientation Deceleration Time parameter sets
the time to decelerate from the maximum output
frequency (E1-04) to 0 Hz.

Refer to Area A:

Deceleration on page 19

0.00 to 600.00 sec

10.00

Yes

– – – Y– – N

P1-13

0620h

Spindle Proximity Sensor
Orientation Enable
Prox Sens Enable

This parameter selects whether or not the drive is
configured with a proximity sensor as described in
Configuration 3. Setting parameter P1-13 = 1 causes
the drive to recognize the values set in proximity
sensor parameters P1-14 and P1-15.

0: Disabled
1: Enabled

0 to 1

0

No

– – – Y– – N

P1-14

0621h

Proximity Sensor Pulse Width
Prox Pulse Width

This parameter defines the pulse width of the
proximity sensor at the P1-02 Creep Speed,
measured in elapsed encoder counts.

0 to 60000 Cnts

0

No

– – – Y– – N

P1-15

0622h

Proximity Sensor Pulse State
Prox Pulse State

This parameter defines whether or not the proximity
sensor is a Normally Open (rising edge) or
Normally Closed (falling edge).

0: Normally Open
1: Normally Closed

0 to 1

0

No

– – – Y– – N

P2-01

060Ah

Marker Offset Selection
MarkerOffset Sel

This parameter determines how the orientation
position offset from the marker pulse is determined.

0: Digital Input
1: Sequential
2: Memobus COM

Refer to Orient Position Offset Selection on
page 25

.

0 to 2

0

No

– – – Y– – N

P2-02

060Bh

Marker Offset 1
Marker Offset 1

This parameter, along with parameters P2-03, P2-
04, and P2-05, sets the orientation (or stopped)
position of the machine. P2-01 governs when P2-02
is active.

Refer to Orient Position Offset Selection

on page 25

.

Note: Counts = Encoder PPR x 4.

0 to 65535 Cnts

0

No

– – – Y– – N

P2-03

060Ch

Marker Offset 2
Marker Offset 2

This parameter is used in conjunction with
parameters P2-02, P2-04, and P2-05 to determine
the orientation position offset from the marker
pulse.

Refer to Orient Position Offset Selection on

page 25

.

Note: Counts = Encoder PPR x 4.

0 to 65535 Cnts

0

No

– – – Y– – N

P2-04

060Dh

Marker Offset 3
Marker Offset 3

This parameter is used in conjunction with
parameters P2-02, P2-03, and P2-05 to determine
the orientation position offset from the marker
pulse.

Refer to Orient Position Offset Selection on

page 25

.

Note: Counts = Encoder PPR x 4.

0 to 65535 Cnts

0

No

– – – Y– – N

P2-05

060Eh

Marker Offset 4
Marker Offset 4

This parameter is used in conjunction with
parameters P2-02, P2-03, and P2-04 to determine
the orientation position offset from the marker
pulse.

Refer to Orient Position Offset Selection on

page 25

.

Note: Counts = Encoder PPR x 4.

0 to 65535 Cnts

0

No

– – – Y– – N

No.

MEMOBUS/

Modbus

Address

Name

Digital Operator Display

Description

Range

Default

Value

Change

During

Run

Control Method/