2 Spindle Orientation

YASKAWA TM.A1000SW.063 Spindle Orientation A1000 Custom Software Supplement

9

F1-31

03B0h

PG 2 Pulses Per Revolution
PG2 Pulses/Rev

Sets the number of encoder pulses per revolution
for the encoder on channel 2.

Note: This parameter is available without a digital
input H1-0… programmed to 16h
(Motor 2 Select).

8 to

16384 PPR

1024 PPR

No

– – – Y– – N

F1-32

03B1h

PG2 Rotation Selection
PG2 Rotation Sel

Determines the direction indicated by the pulses
from the PG feedback encoder for motor 2.

0: Pulse A Leads
1: Pulse B Leads

This parameter is available without a digital input
H1-0… programmed to 16h (Motor 2 Select).

0 to 1

0

No

– – – Y– – N

F1-35

03BEh

PG2 Division Rate for Pulse
Monitor
PG2 Output Ratio

Sets the ratio between the pulse input and the pulse
output of a PG option card.
This parameter is available without a digital input
H1-0… programmed to 16h (Motor 2 Select).

1 to 132

1

No

– – – Y– – N

F1-36

03B5h

PG Option Card Disconnect
Detection 2
PGCardDisconDet1

Sets whether the drive detects a fault when a
PG-X3 card is disconnected.

0: Disabled
1: Enabled

This parameter is available without a digital
input H1-0x programmed to 16h
(Motor 2 Select).

0 to 1

1

No

– – – Y– – N

L3-04

0492h

Stall Prevention Selection during
Deceleration
StallP Decel Sel

Determines how Stall Prevention works during
Run.

The parameter default is changed to 0: Disabled.

0: Disabled
1: General Purpose
2: Intelligent
3: Stall Prevention w/Braking Resistor
4: Overexcitation Deceleration
5: Overexcitation Deceleration 2

Note: Enabling stall prevention extends the decel
time. Other modes such as Intelligent may cause
unintended operation during orient, including
oscillation and inability to maintain position.

0 to 5

0

No

– – – Y– – Y

S1-01

680h

On-Delay Compensation Selection
OnDelay Comp Sel

Parameter S1-01 is used to enable and disable On
Delay Compensation.

0: Disabled
1: Enabled

0 to 1

1

No

– – – Y– – Y

S1-03

682h

Extended Current Sampling Mode
Extend I Sample

Normally there is no need to change S1-03 from its
default setting. If there is a problem with output
voltage weakening when attempting to compensate
for output current distortion as the motor reaches
1000 Hz while decoupled from the load during a
test run, then try setting S1-03 = 1.

0: Disabled
1: Enabled

0 to 1

1

No

– – – Y– – Y

S2-01

691h

Control Mode Switchover
Frequency
HF SwOver Freq

Sets the frequency of switching from Closed Loop
Vector Control to V/f Control.

This function is disabled when 0 or 400 Hz is set,
the inverter runs as V/f Control when 0 is set and
Closed Loop Vector Control when 400 Hz is set.
However, OPE21 occurs when the relations among
Control Mode Switch Frequency (S2-01) and PG
Pulse per Revolution (F1-01) and Numbers of
Motor Poles (E2-04) are set higher than the
permissible input frequency of PG option.

0 to 400 Hz

400

No

– – – Y– – N

S2-02

692h

Control Mode Switchover
Bandwidth
HF CtrlMode SwBW

Sets the hysteresis width of Control Mode Switch.
Increase if shock occurs during Control Mode
switching.

2 to 100 Hz

20

No

– – – Y– – N

No.

MEMOBUS/

Modbus

Address

Name

Digital Operator Display

Description

Range

Default

Value

Change

During

Run

Control Method/

Access Level