2 Spindle Orientation

22

YASKAWA TM.A1000SW.063 Spindle Orientation A1000 Custom Software Supplement

(40h) is active (the spindle remains within the P1-06 window) and the spindle is being commanded to its current offset, the drive
immediately proceeds into final positioning regardless of the error direction.

„

Orient from Stop - Find Marker

When the drive is first powered up, the location of the marker pulse is not known. If the drive is commanded to perform
an Orient from Stop immediately after power up, the drive will first look for the marker as shown in Area A of

Figure 7

.

Once the marker pulse is found, operation is identical to the Orient from Run example discussed in

Orient from Run on

page 18

.

Figure 7

Figure 7 Orient from Stop Including Marker Pulse at P1-02

ORT Set Time (P1-07)

Orient Complete

A/B Pulse Count

(Equivalent to

Shaft Angle)

Z Marker Pulse

Machine Speed

(Hz)

Orient CMD FWD

Accel Time

(C1-0X)

Orient Speed
(P1-01)

Creep Speed
(P1-02)

Rotation due to
External Influence

ORT Set Window
(P1-05)

ORT Rst Window
(P1-06)

(H1-0X = 81h)

(H2-0X = 40h)

Orient Comp Dist

(P1-09)

Creep Distance

(P1-03)

Approach Speed
(P1-04)

Position-Error × P1-08 Gain
Based Speed

0

High P1-08 Gain

Orientation Profile