Fig 1.6 bypass control circuit inputs and outputs, Bypass controller pcb, Fig 1.6 – Yaskawa E7B Drive Bypass System User Manual

Page 14

Advertising
background image

Yaskawa Electric America, Inc.

Installation Guide IG.E7B.02 Rev: 04-11

Date: 11-1-04 Page 12 of 46

Bypass Controller PCB

Fig 1.6

Bypass Control Circuit Inputs and Outputs

Customer provided contact closure inputs must have a minimum rating of 5 mA at 120 VAC.

1

2

3

4

5

6

7

8

9

10

11

12

1

3

14

1

2

3

4

5

6

4

3

1

2

4

2

3

1

AC

+V

FM

+

-

S

HIELD

I

S

OLATED

4-20MADC

OR

0-10VDC

AUTO MODE

S

PEED

REFERENCE

INPUT

6

9

8

7

5

4

3

2

1

REMOTE TRAN

S

FER

S

MOKE PURGE

S

PARE

6

9

8

7

5

4

3

2

1

TB1

TB2

TB

3

TB1

TB1

MIN. RATING

OF CONTACT

S

:

MIN. RATING

OF CONTACT

S

:

CN10

3

A1/A2 FACTORY

S

ETTING I

S

4-20mA CONNECTED TO

DRIVE TERMINAL A2 (A

S

S

ELECTED BY DIP

S

WITCH

S

1(2), (

3

) & (4))

OR

INTERNAL

S

UPPLY

120 VAC LOGIC

CU

S

TOMER

S

UPPLIED

120 VAC LOGIC

A2

PROGRAMMABLE

RELAY #1

MOTOR

RUN

5MA, 120VAC

5MA, 120VAC

120VAC
+/- 15%,

25MA MIN.,

4MA MAX.
LEAKAGE
CURRENT

120VAC COMMON

7

8

9

6

5

4

3

2

1

PE

U

S

ER

S

UPPLY COMMON

ELECTRONIC BYPA

SS

CONTROL PCB

S

+

S

-

R+

R-

1

2

3

J1

J1

3

2

1

DRIVE
TERMINAL

S

7 INPUT

DRIVE
TERMINAL

S

6 INPUT

AC

AM

+V

(+15VDC, 20mA)

A2

4-20MADC OR 0-10VDC

(A

S

S

ELECTED BY

DIP

S

W.

S

1(2).

FACTORY

S

ETTING I

S

4-20MADC)

TB5

TB4

DRIVE AM MONITOR OUPUT

4-20MADC OR 0-10VDC

(A

S

S

ELECTED BY JUMPER J

3

.

FACTORY

S

ETTING I

S

4-20MADC)

PROGRAMMABLE

RELAY #2

PROGRAMMABLE

RELAY #

3

(FACTORY

S

ETTING

I

S

S

Y

S

TEM FAULT)

(FACTORY

S

ETTING)

ELECTRONIC BYPA

SS

CONTROL PCB

ELECTRONIC BYPA

SS

CONTROL PCB

S

AFETY INTERLOCK

S

(+15VDC,
20mA)

3

2

4-20
MADC

1

3

2

0-10

VDC

1

J2

J

3

(A

S

S

ELECTED BY

DIP

S

WITCH

S

1 (2,

3

, & 4).

S

EE

S

H. 2, TABLE 4.

FACTORY

S

ETTING

I

S

4-20MADC,

CONNECTED TO DRIVE
ANALOG INPUT 2 (A2).)

BA

S

/DAMPER INTERLOCK

AUTO MODE RUN/

S

TOP

(FACTORY

S

ETTING

I

S

HAND MODE)

(FACTORY

S

ETTING

I

S

AUTO MODE)

FACTORY

S

ETTING

S

TB

3

(4)

FM

AM

TB5(6)

DRIVE
TERMINAL

S

N

DRIVE
TERMINAL

S

P

NOT
U

S

ED

S

EE THE

APPROPRIATE

TECHNICAL

MANUAL FOR

NETWORK

CONNECTION

S

OPTION

S

J, U OR V

S

ERIAL

COMMUNICATION

S

META

S

Y

S

(J),

APOGEE (U) OR,

R

S

422/4

8

5

MODBU

S

(V)

DRIVE FM MONITOR OUTPUT
4-20MADC OR 0-10VDC
(A

S

S

ELECTED BY JUMPER J2.

FACTORY

S

ETTING I

S

4-20MADC)

Advertising