3 Wiring

3.1.1 Connection Diagram

3-2

3.1 Wiring for Re-engineered AC SERVOPACKs

CACR-SR††BF1†††

3.1.1 Connection Diagram

3.1.2 Names and Description of Main Circuit Terminals

R
S
T

r
t

Y3

Y4

U
V
W

Main circuit power supply

Three-phase 200V/220V

50/60 Hz

Control circuit power supply

Single-phase 200V/220V

50/60Hz

M

AC Servomotor

Regenerative

resistor

CN1

CN2

CN3

I/O signals

y

Speed reference

y

PG signal

y

Operation signal

Encoder

Digital operator

JUSP-OP05A

PG

A
B
C

D

Encoder signal

conversion function

built-in

Re-engineered AC SERVOPACK

Terminal Symbol

Name

Description

(R) (S) (T)

Main circuit input
terminals

Three-phase 200 to 230 VAC

+10 to -15 %

, 50/60 Hz

(U) (V) (W)

Servomotor
connection terminals

Connect (U) to the terminal A, (V) to the terminal B, (W) to the terminal C of
Servomotor.

(r) (t)

Control circuit input
terminals

Single-phase 200 to 230 VAC

+10 to -15 %

, 50/60 Hz

Ground terminal

Connect to the power supply ground terminal and the Servomotor D terminal.

(Y3) (Y4)

Regenerative resistor
terminals

Regenerative resistor connection terminals (normally not to be connected
externally.)