3 warning displays, 3 warning displays -6 – Yaskawa CACR-SRxxBF User Manual

Page 55

Advertising
background image

5 Maintenance, Inspection and Alarm/Warning Display

5-6

5.3 Warning Displays

The relation between warning displays and warning code outputs are shown in table 5.2.

Table 5.2 Warning Displays and Outputs

Warning

Display

Warning Name

Meaning

Warning Code Output

ALO1

ALO2

ALO3

A.910

Overload

This warning occurs before the overload alarms (A.710 or
A.720) occur. If the warning is ignored and operation con-
tinues, an overload alarm may occur.

L

H

H

A.911

Vibration

Abnormal vibration at the motor speed was detected. The
detection level is the same as A.520. Set whether to output
an alarm or warning by “Vibration Detection Switch” of
Pn310.

L

H

H

A.920

Regenerative Overload

This warning occurs before the regenerative overload
alarm (A.320) occurs. If the warning is ignored and opera-
tion continues, a regenerative overload alarm may occur.

H

L

H

A.930

Absolute Encoder Battery
Voltage Lowered

This warning occurs when the absolute encoder battery
voltage is lowered.

L

L

H

A.941

Change of Parameters
Requires Setting Validation

The change of the parameters can be validated only after
turning the power ON from OFF.

L

H

H

Advertising