5.2 Alarm Display Table

5-3

5

5.2 Alarm Display Table

The re-engineered SERVOPACK model CACR-SR††BF has the same alarm function as that of

Σ-III series

SERVOPACK.
If an alarm occurs, the servomotor can be stopped by doing either of the following operations.

• DB stop: Stops the servomotor immediately using the dynamic brake.
• Zero-speed stop: Stops the servomotor by setting the speed reference to “0.”

Table 5.1 Alarm Display Table

Alarm

Display

Alarm Name

Meaning

Servomo-

tor Stop

Method

Alarm
Reset

Alarm Code Output

Servo
Alarm

(ALM)

Output

ALO1

ALO2

ALO3

A.020

Parameter Checksum
Error

The data of the parameter in the
SERVOPACK is incorrect.

DB stop

N/A

H

H

H

H

A.021

Parameter Format Error

The data of the parameter in the
SERVOPACK is incorrect.

DB stop

N/A

A.022

System Checksum Error

The data of the parameter in the
SERVOPACK is incorrect.

DB stop

N/A

A.023

Parameter Password Error The data of the parameter in the

SERVOPACK is incorrect.

DB stop

N/A

A.030

Main Circuit Detector
Error

Detection data for power circuit is
incorrect.

DB stop

Available

A.031

Main Circuit (Power
Pack) Alarm

The switch S2 is set incorrectly

DB stop

N/A

A.040

Parameter Setting Error

The parameter setting is outside the
allowable setting range.

DB stop

N/A

A.041

Dividing Pulse Output
Setting Error

The PG dividing pulse setting
(Pn212) is outside the allowable set-
ting range or not satisfies the setting
conditions.
This alarm may occur when using-
SR††BF1††E or -
SR††BF1††Y.

DB stop

N/A

A.042

Parameter Combination
Error

Combination of some parameters
exceeds the setting range.

DB stop

N/A

A.050

Combination Error

SERVOPACK and servomotor capac-
ities do not match each other.

DB stop

Available

A.051

Unsupported Product
Alarm

The serial converter unit unsup-
ported was connected.

DB stop

N/A

A.0b0

Servo ON reference
Invalid Alarm

The Host controller reference was
sent to turn the Servo ON after the
Servo ON function was used with the
Digital Operator or SigmaWin+.

DB stop

Available

A.100

Overcurrent or Heat Sink
Overheated

An overcurrent flowed through the
IGBT.
Heat sink of SERVOPACK was over-
heated.

DB stop

N/A

L

H

H

H

A.300

Regeneration Error
Detected

Regenerative circuit or regenerative
resistor is faulty.

DB stop

Available

L

L

H

H

A.320

Regenerative Overload

Regenerative energy exceeds regen-
erative resistor capacity.

Zero speed

stop

Available

A.330

Main Circuit Power
Supply Wiring Error

The power supply to the main circuit
does not match the parameter Pn001
setting.

DB stop

Available

A.400

Overvoltage

Main circuit DC voltage is exces-
sively high.

DB stop

Available

H

H

L

H

A.410

Undervoltage

Main circuit DC voltage is exces-
sively low.

Zero speed

stop

Available