See table 4.3, Table 4.4, See table 4.2 – Yaskawa CACR-SRxxBF User Manual

Page 43

Advertising
background image

4 Settings and Display

4.2.1 Pin Settings

4-6

The settings shown in Tables 4.3, 4.4 and 4.5 are valid on the re-engineered AC SERVOPACKs for CACR-
SR††BB and -SR††BZ, but invalid for the re-engineered AC SERVOPACK for CACR-SR††BE and -
SR††BY.

Table 4.2

Servomotor Encoder Specifications

Setting

SW2

Status

Encoder Type

Model

Code

No. of

Pulses

DSW1 DSW5

1

2

3

4

5

6

7

Conventional

incremental

F

1000 P/R

0

0

ON

ON

ON

ON OFF OFF OFF

H

1440 P/R

1

ON

ON

ON

ON OFF ON OFF

E

1500 P/R

2

OFF OFF ON

ON OFF OFF OFF

K

2000 P/R

3

OFF ON OFF ON OFF OFF OFF

C

2500 P/R

4

ON

ON

ON OFF OFF OFF OFF

D

4000 P/R

5

ON OFF ON OFF OFF OFF OFF

B

5000 P/R

6

ON

ON OFF OFF OFF OFF OFF

A

6000 P/R

7

OFF ON OFF OFF OFF OFF OFF

M

30000 P/R

9

ON

ON

ON

ON

ON

ON OFF

Multiplexed incremental

3

2048 P/R

1

0

ON OFF OFF ON OFF OFF OFF

2

8192 P/R

1

OFF OFF OFF OFF OFF OFF OFF

Absolute

W

1024 P/R

2

0

OFF ON

ON

ON OFF OFF OFF

S

8192 P/R

1

OFF OFF OFF OFF OFF OFF OFF

Table 4.3 Motor Rated Speed

(Valid for CACR-SR††BB and -SR††BZ)

Servomotor Rated Speed

SL5

SW3-7

1000 r/min

-1

1-2

ON

1500 r/min

-1

2-3

ON

2000 r/min

-1

2-3

OFF

3000 r/min

-1

2-3

ON

Table 4.4 Speed Amplifier Gain (Valid for CACR-SR††BB and -SR††BZ)

SW3 Specifications

Factory Settings

Pin No.

Functions

OFF

ON

M-series

F-series

S-series

1 kW and

1.5 kW

S-series

0.5 kW or

less, and

3.0 kW

D-series

1

Proportional gain 100 k

Valid

Invalid

ON

OFF

OFF

OFF

2

Proportional gain 220 k

Valid

Invalid

OFF

ON

ON

OFF

3

Imperfect integration 6.6 M

Valid

Invalid

OFF

OFF

OFF

OFF

4

Integration 0.033 uF

Invalid

Valid

ON

OFF

ON

ON

5

Integration 0.033 uF

Invalid

Valid

OFF

OFF

OFF

OFF

6

Integration 0.22 uF

Invalid

Valid

OFF

ON

OFF

OFF

7

For servomotor rated speed

ON

ON

ON

OFF

8

Mode selection switch

Valid

Invalid

OFF

OFF

OFF

OFF

Set according to
the number of
encoder pulses.

When the SERVOPACK output dividing
ratio is set to 1/1
Pn212 is enabled when SW2-8 is ON.

Advertising