13 Appendix 2 Parameter Cross Reference

26

YASKAWA PL.P1000.01 P7 to P1000 - Product Transition Guide

DC Injection
Braking

DC Injection
Braking Start
Frequency

b2-01

0.5 Hz

b2-01

0.5 Hz

DC Injection
Braking current

b2-02

50%

b2-02

50%

DC Injection
Braking Time at
Start

b2-03

0.00 s

b2-03

0.00 s

DC Injection
Braking Time at
Stop

b2-04

0.00 s

b2-04

0.50 s

Motor Pre-Heat
Current

b2-09

0%

b2-02

50%

The same current setting is used for DC injection at start and stop.
Default current is 50%

Motor Pre-Heat
Current 2

b2-10

5%

b2-02

50%

Speed Search

Speed Search
Selection

b3-01

2

b3-01

0

b3-01

b3-01

b3-24

0: Disabled
(Speed Estimation)

0: Disabled

1: Speed

Estimation

1: Enabled
(Speed Estimation)

1: Enabled

1: Speed

Estimation

b3-24

0

2: Disabled
(Current Detection)

0: Disabled

0: Current

Detection

3: Enabled
(Current Detection)

1: Enabled

0: Current

Detection

Speed Search
Operating
Current

b3-02

120%*

b3-02

120% *Determined by parameter A1-02, Control Method Selection

Speed Search
Deceleration
Time

b3-03

2.0 s

b3-03

2.0 s

Speed Search
Delay Time

b3-05

0.2 s

b3-05

0.2 s

Bi-Directional
Speed Search
Selection

b3-14

1

b3-14

1

b3-14

b3-14

0: Disabled

0: Disabled

1: Enabled

1: Enabled

Timers

Timer Function
On-Delay Time

b4-01

0.0 s

b4-01

0.0 s

Timer Function
Off-Delay Time

b4-02

0.0 s

b4-02

0.0 s