Yaskawa P7 to P1000 User Manual

Page 8

Advertising
background image

3 P7 to P1000 Feature Specifications

8

YASKAWA PL.P1000.01 P7 to P1000 - Product Transition Guide

Harmonic Counter Measures

12 Pulse: 30 HP and Above
Filters/Reactors (Options)

12 Pulse: 40 HP and Above (specific models)
Filters/Reactors (Options)

Built-In DC Bus
Reactor

240 Vac: 30 to 150 HP
480 Vac: 30 to 500 HP

240 Vac: 30 to 175 HP
480 Vac: 30 to 1000 HP
600 Vac: 30 to 250 HP

Ambient Temperature

ºC

-10ºC to +40ºC (IP21)
-10ºC to +45ºC (IP00)

-10 to +40 °C
(IP20/NEMA Type 1 Enclosure)
-10 to +50 °C (IP00/Open-Chassis Enclosure)

Storage Temperature

ºC

-20 ºC to +60 ºC

-20 ºC to +60 ºC

Network Communications

Standard

Modbus RTU
via terminal I/O RS485/422

Modbus RTU via terminal I/O
RS-485/RS-422

Optional

DeviceNet, Profibus-DP, ControlNet,
Ethernet

Ethernet/IP, Modbus TCP, DeviceNet,
ProfiNet, Profibus DP, RS-485, Mechatrolink
II, EtherCAT

Unique Feature/Function

HSB – High Slip Braking

Overexcitation Braking

Feature

Item

P7

P1000