17

Ot

he

r

F

u

nc

ti

o

n

s

Di

sp

la

y

Status Indicator LED

RUN and ALARM provided as standard LED’s

Digital Operator

(JVOP-140)

Available to monitor frequency reference, output frequency,
output current. 3 character, 7 segment LED Display.

Terminals

Main circuit: screw terminals
Control circuit: plug-in screw terminal

Wiring Distance between

Inverter and Motor

328ft (100m) or less‡

Enclosure

Open chassis

Cooling Method

Cooling fan is provided for 200V, 0.75kW (3-phase), 400V,
1.5kW (single-phase), others are self-cooling

E

n

vi

ron

m

e

n

ta

l

Co

nd

itio

ns

Ambient Temperature

Open chassis: -10 to +50

°

C (14 to 122

°

F)

(not frozen)

Humidity

95% RH or less (non-condensing)

Storage Temperature†

-4 to 140

°

F (-20 to +60

°

C)

Location

Indoor (free from corrosive gases or dust)

Elevation

3280ft (1000m) or less

Vibration

Up to 9.8m / S

2

(1G) at less than 20Hz, up to 2m / S

2

(0.2G) at

less than 20 to 50Hz

†Temperature during shipping (for short period)

‡ If the wiring distance between inverter and motor is long, reduce the inverter carrier frequency.

For details, refer to “Reducing motor noise or leakage current (n46)”on page 79.

Voltage Class

200V single- / 3-phase

Model

CIMR-J7AU!!!!

3-phase

20P1

20P2

20P4

20P7

21P5

22P2

23P7

Single-phase

B0P1

B0P2

B0P4

B0P7

B1P5

-

-

Advertising