Yaskawa VS mini J7 Series User Manual

Page 28

Advertising
background image

28

34

0122H

Parameter selection at
electronic thermal motor
protection

Setting unit: 1min
Setting range: 1 ~ 60min

8 min

94

35

0123H

Cooling fan operation
selection

0: Controls the cooling fan OFF / ON
1: Operates when power is ON.

0

96

36

0124H

Multi-function input
selection 2

1: Not used
2: Reverse run reference (2 wire

sequence)

3: External fault (N. O. contact input)
4: External fault (N. C. contact input)
5: Fault reset
6: Multi speed reference 1
8: Multi speed reference 2
7: Multi speed reference 3
9: Not used
10: Jog reference
11: Accel / decel time switching refer-

ence

12: External baseblock reference
(N. O. contact input)
13: External baseblock reference
(N. C. contact input)
14: Speed search command from Max.

output frequency

15: Speed search command set fre-

quency

16: Accel / decel hold
17: Local / remote switching
18: Communication / control circuit ter-

minal switching

19: Emergency stop fault
(N. O. contact input)
20: Emergency stop alarm
(N. O. contact input)
21: Emergency stop fault
(N. C. contact input)
22: Emergency stop alarm
(N. C. contact input)
23~ 33: Unused

2

82

37

0125H

Multi-function input
selection 3

0: Forward / reverse command
(3 wire sequence)
Others are the same as parameter 36

5

84

38

0126H

Multi-function input
selection 4

Same as parameter 36

3

84

39

0127H

Multi-function input
selection 5

Same as parameter 36
34: Up/down reference
35: Self-test
(Note: valid power ON / OFF)

6

84

No.

Register

No. for

Trans-

mission

Name

Description

Initial

Setting

*User

Setting

Ref.

Page