On : blinking : off – Yaskawa VS mini J7 Series User Manual

Page 48

Advertising
background image

48

Status indicator lamp

Operation Check Points

Motor rotates smoothly.

Motor rotates in the correct direction.

Motor does not have abnormal vibration or noise.

Acceleration or deceleration is smooth.

Current is appropriate for the load (No overload).

Status indicator LED’s and digital operator display are correct.

Operation Steps

Operator

Display

12-LED

Display

Status

Indicator LED

1. Turn the local pot (volume control) fully counter clockwise

after turning the power ON.

0.00

RUN

ALARM

2. Press DSPL 5 times to illuminate Lo/RE
Select Lo (local mode) using or key

Lo

RUN

ALARM

3. F/R blinks.

Select FWD/REV run using keys

Never select REV when reverse run
is prohibited.

For
or
REV

RUN

ALARM

4. Press DSPL to illuminate FREF. Then press RUN.

0.00

RUN

ALARM

5. Operate the motor by turning the volume clockwise.

(Frequency reference corresponding to the volume position
is displayed.)

If the volume is switched rapidly, the motor also
accelerates or decelerates rapidly corresponding to
the volume movement. Pay attention to load status
and adjust the volume to the desired speed.

0.00 to 60.00
Minimum
output
frequency is
1.5Hz

RUN

ALARM

Lo/RE

: ON

: Blinking

: OFF