ATM Port Redundancy Configuration Screen

Local Management

3-31

Reset all configurations in the ATM Port Redundancy Configuration screen to their factory
default settings.

To access the ATM Port Redundancy Configuration screen from the ATM screen, perform the
following steps:

1. Use the arrow keys to highlight the ATM PORT REDUNDANCY menu item from the

Physical Port Configuration Menu screen.

2. Press ENTER. The ATM Port Redundancy Configuration screen,

Figure 3-12

, displays.

Figure 3-12

ATM Port Redundancy Configuration Screen

The following list explains each ATM Port Redundancy Configuration screen field:

Redundancy Status (Toggle)

Used to enable or disable the APIM redundancy feature of the VHSIM2-A6DP. This field toggles
between Enabled and Disabled. The default value of this field is Enabled.

NOTE: There MUST be two APIMs installed in the VHSIM2-A6DP to make the
redundancy feature available.

NOTE: The ATM Port Redundancy Configuration screen refreshes approximately every
3 seconds.

RETURN

SAVE

EXIT

Redundancy Status: [Enabled]

Primary port: 1

Active port: 1

Activation of redundant port: [Automatic]

Revert to Primary port: [Automatic]

Periodic test status: [Enabled]

Periodic test time: 01:00.00

Port Usability Status: No test performed since system startup

TEST PORTS NOW

RESET TO FACTORY DEFAULTS

2825_17