Amprobe AMB-110 Insulation-Resistance-Tester User Manual

Page 37

Advertising
background image

32

Measuring range Riso: 0.12 Me up to 10 Te*)

Display range Riso

Resolution

Accuracy

0 - 999 ke

1 ke

(5 % of reading + 3 digits)

1.00 - 9.99 Me

10 ke

10.0 - 99.9 Me

100 ke

100 - 999 Me

1 Me

1.00 - 9.99 Ge

10 Me

10.0 - 99.9 Ge

100 Me

100 - 999 Ge

1 Ge

1.00 -10.00 Te

10 Ge

(15 % of reading + 3 digits)

*Full-scale value of insulation resistance is defined according the following equation:
R

FS

= 1 Ge * U

test

[V]

DC test voltage:

• Voltage value: Any value within 500 V and 10 kV, steps by 25 V.
• Accuracy: -0 / +10 % + 20 V.
• Output power: 10 W max.

Display range Test voltage (V)

Resolution

Accuracy

0 - 9999 V

1 V

(3 % of reading + 3 V)

10 kV

0,1 kV

(3 % of reading)

Current:

Display range I (mA)

Resolution

Accuracy

1.00 - 5.50 mA

10 A

(5 % of reading + 0.05 nA)

100 - 999 A

1 A

10.0 - 99.9 A

100 nA

1.00 - 9.99 A

10 nA

100 - 999 nA

1 nA

10.0 - 99.9 nA

0.1 nA

0.00 - 9.99 nA

0.01 nA

Noise current rejection (resistive load)

Filter option

Maximum current @ 50Hz (mA r.m.s).

Fil0

1.5

Fil1

2.5

Fil2

4.5

Fil3

5

Advertising