Generator capability vs resistance, Electric absorption ratio dar, Polarization index pi – Amprobe AMB-110 Insulation-Resistance-Tester User Manual

Page 38: Dielectric discharge test dd

Advertising
background image

33

Generator Capability vs Resistance

0

2

4

6

8

10

12

0.1

1

10

100

[ M ]

[ k

V

]

Utest=10kV

Utest=5kV

Electric absorption ratio DAR

Display range DAR

Resolution

Accuracy

0.01 - 9.99

0.01

(5% of reading + 2digits)

10.0 - 100.0

0.1

(5% of reading)

Polarization index PI

Display range PI

Resolution

Accuracy

0.01 - 9.99

0.01

(5 % of reading + 2 digits)

10.0 - 100.0

0.1

(5% of reading)

Dielectric discharge test DD

Display range DD

Resolution

Accuracy

0.01 - 9.99

0.01

(5 % of reading + 2 digits)

10.0 - 100.0

0.1

(5% of reading)

Capacitance range for DD test: 5 nF to 50 F.

Step voltage

• DC test voltage:
• Voltage value: Any value within 2000 V (400 V, 800 V, 1200 V, 1600 V, 2000 V) and 10 kV (2000

V, 4000 V, 6000 V, 8000 V, 10 kV), steps by 125 V.

• Accuracy: -0 / +10 % + 20 V.

Display range Test voltage (V)

Resolution

Accuracy

0 - 9999 V

1 V

(3 % of reading + 3 V)

10 kV

0,1 kV

(3 % of reading)

Advertising